8514-042-001A
July 2013
OPERATOR’S MANUAL
for MANUAL (OPL) COMPACT DRYER
The dryer must not be stored or installed where it will be exposed to water and/or weather.
WARNING: For your safety the information in this manual must be followed to
minimize the risk of fire or explosion or to prevent property damage, personal
injury or death.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.
-WHAT TO DO IF YOU SMELL GAS
-Do not try to light any appliance.
-Do not touch any electrical switch: do not use any telephone in your building.
-Clear the room, building or area of all occupants.
-Immediately call your gas supplier from a neighbor’s telephone. Follow the
gas supplier’s instructions.
-If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
You, the purchaser, must post in a prominent location instructions to be followed in the event the user smells
gas. Consult your local gas supplier for procedure to be followed if the odor of gas is present.
Post the following
For Your Safety
caution in a prominent location:
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY
THIS MACHINE IS FOR DRYING ONLY FABRICS CLEANED IN WATER.
To
avoid possibility of fire, including spontaneous combustion, do not dry oiled floor mops, items
containing foam rubber or similarly textured rubberlike materials or any material on which you
have used a cleaning solvent or which contains flammable liquids or solids (such as gasoline,
kerosene, waxes, etc.)
It is important that you read this Manual and retain it for future reference.
For service or replacement parts, contact the distributor in your area or:
Seitenansicht 0
1 2 3 4 5 6 ... 12 13

Inhaltsverzeichnis

Seite 1 - OPERATOR’S MANUAL

8514-042-001A July 2013 OPERATOR’S MANUAL for MANUAL (OPL) COMPACT DRYER The dryer must not be stored or installed where it will be exposed to water

Seite 2 - French Language Warnings

10 7. DRYER IGNITION (SOLID STATE IGNITION). The solid-state ignition system lights the main burner gas by spark. The gas is ignited and burns

Seite 3

11 OPERATING INSTRUCTIONS 1. Place the clothes load to be dried in the dryer drum and close the loading door. 2. Set the temperature selector to t

Seite 4

12 SERVICING THE DRYER Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper operation. A

Seite 5

13 Maintenance Requiring Technical and Mechanical Skills: (Disconnect power to dryer before beginning.) Quarterly A. Check tumbler shaft retain

Seite 6

Dexter Laundry, Inc. 2211 W. Grimes Fairfield, Iowa 52556, USA French Language Warnings AVERTISSEMENT. Assurez-vous de bien suivre le

Seite 7

3 TABLE OF CONTENTS Page No. Warnings about use and operation ...

Seite 9

5 INSTALLATION AND OPERATING INSTRUCTIONS This dryer may have been supplied as part of a washer/dryer stacked appliance. If so, refer to the wa

Seite 10

6 IV. Front 48 in. (1220 mm) to allow use of dryer. V. Top Refer to figure labeled “Vertical Clearance Dimensions”. AB. 0

Seite 11

7 3. MAKE-UP AIR. Adequate make-up air, 440 CFM (12.5 m3/Min.), must be supplied to replace air exhausted by dryers on all types of installations

Seite 12

8 CAUTION: The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that

Seite 13

9 Installation of several dryers, where a main discharge duct is necessary, will need the following considerations for installation (see Figure